Heat line C24 Pdf User Manuals. View online or download Heat line C24 Installation, Servicing And User Instructions Manual. The boiler’s ‘Log Book’ must be completed at each Service visit. By means of a manual switch the C24/C28 can be set to operate in one of two operating modes, . Boiler Manuals for the Heatline Compact C24 appliance.

Author: Faekora Malarr
Country: Japan
Language: English (Spanish)
Genre: Art
Published (Last): 16 January 2017
Pages: 128
PDF File Size: 1.46 Mb
ePub File Size: 14.17 Mb
ISBN: 798-8-23529-403-5
Downloads: 68975
Price: Free* [*Free Regsitration Required]
Uploader: Samunris

Re-connect sensing tube and all the electrical leads 7.

Heatline c24 manual download

Re-assemble the boiler in reverse order Secondary Heat Exchanger heatline c24 manual 1. Permanent temperature difference between flow and return heating sensors. Replace gas supply, pressure or gas valve. Flow and return heating sensors fault.

Heat Line C24 Installation, Servicing And User Instructions Manual

Check gas soundness and correct boiler operation. The air pressure switch is located on the top of the expansion vessel 4. Ensure all joints are sound. You should unscrew the heatline c24 manual pump vent plug. Remove the boiler casing following the steps below 1. Heating circuit pressure sensor fault. Isolate the appliance and switch off the electricity 2.

Heat Line C24 Manuals

Re-assemble in reverse order Burner replacement 1. Verify the main board.

Release the main gas connection between heatline c24 manual gas valve supply tube and gas inlet valve, retaining the washer for use on reassembly 7. When the demand heatline c24 manual central heating is fulfilled, the burner will shut down and the appliance will come to stand-by mode, until the next heatlinr water or heating demand.

Try This PDF:   CONVERTER ARQUIVO DWG EM PDF DOWNLOAD

Verify the flame detection electrode. Release the union connections on the connection pipes, retaining the washers for re-assembly 6.

Refit in reverse order to removal, the polarity of the wires to the modulating coil is not important, replace any damaged washers as required heatline c24 manual Verify the wiring harness. Reset the appliance F68 Fluctuation of flame signal Verify the return gas circuit gas valve open. Heatline c24 manual potentiometers are placed on the control panel.

Unclip the sensor from the pipe 5. Remove the pump assembly.

Troubleshooting Manual |

Is the central heating? F70 User interface incompatible with the main board Verify that the appliance DSN code on the screen matches the product code of the nameplate. Refit in reverse order to removal, the polarity of the wires to the modulating coil is not important, healtine any damaged washers as required. Fit the replacement body in reverse order ensuring that the pump washers are sound and fitted correctly and the heatline c24 manual of the electrical connections are correct Remove the pipe clips on the pipes of heat exchanger 5.

Remove the sensing tube and electrical connections from the air pressure switch, noting which tube is connected to which port as shown heatline c24 manual the picture below 5. Make sure that all electrical connections are fit into the right home 7. Primary pressure sensor will turn off your appliance whenever the circuit pressure will fall under 0.

Try This PDF:   LA TEOLOGIA FEMINISTA EN LA HISTORIA TERESA FORCADES PDF

Replace air pressure switch or overheat sensor. Verify the pump speed. Heatline c24 manual the chamber cover by heatline c24 manual all the screws should be two on each side. After activating this function system will need to be manually re-set.

Replace the heat exchanger F77 Fault in gas valve motor Verify the gas valve connections. Verify the igniter unit Heatlinr Ignition fault Verify the return gas circuit gas valve open. Verify that the fl ow and return heating isolation valves are open F22 Water pressure of the installation Fill the installation.

Remove the boiler casing following the steps below. A delay up to 45 sec may be observed- depending on a model. Primary pressure sensor- it is hydraulically heatline c24 manual sensor that checks and monitors water shortage and water general pressure in the main circuit.

Re-assemble in hextline order Attention! A volt, duel speed fan expels combutsion products from the chamber to outside air via an associated flue system.